Data Center
how can we help you
You can contact us any way that is convenient for you. We are available 24/7 via email or telephone.
Contact Us
New Products

Data center usually refers to the centralized processing, storage, transmission, exchange and management of information in a physical space. The key physical infrastructure of data center to guarantee critical running contains power supply system, refrigeration system, cabinet system, fire protection system and monitoring system.

  • As cloud computing has penetrated all walks of life, many enterprises build small information computer rooms to support network access and basic IT applications. Rack-mounted air conditioners provide flexible and efficient cooling solutions inside the data center, using a rack-mounted design concept that is flexible, compact, and suitable for circulating cooling inside the cabinet and integrating an independent micro data center with the main equipment inside the cabinet. The indoor part is installed at the bottom of the cabinet and can self-adapt to load changes inside the cabinet. The unit adopts air-cooled heat dissipation, environmentally friendly refrigerant, a DC inverter compressor, and a three-speed adjustable internal fan to achieve high energy efficiency and high apparent heat ratio operation of the whole machine. Cooling Capacity Cooling Type 3.5KW~12.5KW Air Cooling Refrigerant Centrigufal Fan R410A/R134A EC Fan Compressor Type Program Invertor Compressor Modbus (Standard)

    Tags : Rack Mounted Precision Air Conditioning Precision Air Conditioner PACU Air Cooled Precision Air Conditioner Precision Air Cooled Unit Precision Cooling System Precision Environmental Control Air Conditioner

    Read More
  • The modular data center is designed according to the basic rules of energy efficiency and optimal management, and contains cooling modules, power supply and distribution modules, as well as network, cabling, monitoring and fire protection modules. Modular data center has a power supply interface to the outside, a refrigeration interface, a network interface and a comprehensive wiring interface reserved through overhead weak and strong power slots. The use of in row air conditioning for cooling enables a high sensible heat ratio of 100%, effectively reducing the overall humidification and dehumidification energy consumption of the data center. In row air conditioning minimizes the airflow circulation path, improves the heat density of the data center under the premise of effective cooling, and realizes energy-saving cooling of the data center. Power 3N-380V-50HZ Operating Voltage 380v/220v Cooling In-row Precision Air Conditioning UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz Certification CE,ISO Monitoring System Power supply, battery, power distribution, air conditioning,etc.

    Tags : Modular Data Center In Row Air Conditioning Closed Cold Aisle Integrative Modular Data Center Data Center Solutions

    Read More
  • As an important field within the company,how to protect the security performance of the data center computer room is very important. The micro module computer room is the choice for the modernization of the data room. The modular data room is to divide the large data center into several independent areas (independent modules). The construction scale, power load, resource allocation, etc. of each area are designed and constructed according to the unified standard. With the continuous development of IT equipment requirements, independent modules can be continuously added and gradually built as needed to achieve rapid construction and rapid replication of existing data centers. Power 3N-380V-50HZ Operating Voltage 380v/220v Cooling In-row Precision Air Conditioning UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz Certification CE,ISO Monitoring System Power supply, battery, power distribution, air conditioning,etc.

    Tags : In Row Air Conditioning Closed Cold Aisle Integrative Modular Data Center Data Center Solutions All In One Data Center Solutions Servers and Data Centers Modular Data Center

    Read More
  • COOL RACK Series rack-mounted air conditioner is a cabinet-level temperature control product specially designed for integrated cabinets data center, modular data center or high heat density data centers. It can be placed in the cabinet close to the heat source and can accurately handle the output of the equipment in the cabinet. The high sensible heat can effectively prevent the generation of local hot spots, reduce the return air distance, increase the return air temperature, and improve the energy efficiency ratio. Cooling Capacity Cooling Type 3.5KW~12.5KW Air Cooling Refrigerant Centrigufal Fan R410A/R134A EC Fan Compressor Type Program Invertor Compressor Modbus (Standard)

    Tags : Rack Mounted Precision Air Conditioning Precision Air Conditioner PACU Air Cooled Precision Air Conditioner Precision Air Cooled Unit Precision Cooling System Precision Environmental Control Air Conditioner

    Read More
  • SHUYI CJA Series Rack Mounted Precision Air Conditioner is acabinet-level temperature control product specially designed forintegrated cabinets, micro-modules or high heat density data centers.ltcan be placed close to the heat source in the cabinet and it can accuratelyhandle the high sensible heat generated by the equipment in the cabinet. ltcan effectively prevent the generation of local hot spots,reduce the returnair distance, increase the return air temperature,improve energy efficiencyratio,have significant energy saving effect and effectively develop greendata centers for long term. Cooling Capacity Cooling Type 3.5KW~12.5KW Air Cooling Refrigerant Centrigufal Fan R410A/R134A EC Fan Compressor Type Program Invertor Compressor Modbus (Standard)

    Tags : Rack Mounted Precision Air Conditioning Precision Air Conditioner PACU Air Cooled Precision Air Conditioner Precision Air Cooled Unit Precision Cooling System Precision Environmental Control Air Conditioner

    Read More
  • Embedded power supply system integrates multiple function, including DC current limiting, peak surge absorption, comprehensive automatic protection, battery intelligent management, unattended, intelligent remote monitoring and other functions. The components of the system are divided into two parts: power supply and battery, the cabinet structure is divided into one-piece and split type,indoor or outdoor design. The power supply section includes: AC distribution unit, rectifier module, monitoring unit and control circuit.Each functional unit is designed in standardized sizes, with power supply heights ranging from 1U to 9U.It meets the wide range of DC outputs from 30A to 400A and is a DC power supply system with a wide range of application scenarios. Rack height Installation method 1U-9U Embedded installation input voltage Output voltage range 220Vac,50Hz 42-58Vdc

    Tags : 48V DC Power Supply Power Supply System DC Power Supply

    Read More
  • SHUYI lead-acid battery (VRLA) is a battery whose electrodes are mainly made of lead and its oxides, and the electrolyte is a sulfuric acid solution. The nominal voltage of a single-cell lead-acid battery is 2.0V, which can be discharged to 1.5V and charged to 2.4V; In applications, 6 single-cell lead-acid batteries are often connected in series to form a nominal 12V lead-acid battery , as well as 24V, 36V, 48V, etc. Capacity Efficiency 100-3000A Above 99.99% Nominal Voltage Openning Pressure 2V 10-20Kpa Rated Life Warranty Up to 15 years 3 years

    Tags : Portable Backup UPS With Charge By Solar 12V VRLA Battery 2V VRLA Battery

    Read More