Green Energy Saving Modular Data Center
Green Energy Saving Modular Data Center
Green Energy Saving Modular Data Center
Green Energy Saving Modular Data Center

Green Energy Saving Modular Data Center

As an important field within the company, how to protect the security performance of the data center computer room is very important. The micro module computer room is the choice for the modernization of the data room. The modular data room is to divide the large data center into several independent areas (independent modules). The construction scale, power load, resource allocation, etc. of each area are designed and constructed according to the unified standard. With the continuous development of IT equipment requirements, independent modules can be continuously added and gradually built as needed to achieve rapid construction and rapid replication of existing data centers.

Power

3N-380V-50HZ

Operating Voltage

380v/220v

 

 

Cooling

In-row Precision Air Conditioning

UPS Power Supply

380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz

 

 

Certification

CE,ISO

Monitoring System

Power supply, battery, power distribution, air conditioning,etc.

 

 

 

Features
 
  • I-Module Modular Data Center Solutions

    The modular data center is mainly composed of cabinets, closed channels, power supply and distribution systems, refrigeration systems, intelligent monitoring systems, generic cabling and fire protection systems. A single modular data center is configured according to the maximum N cabinets (including server cabinets, network cabinets, and generic cabling cabinets). The module (excluding UPS) covers an area of 35 m2. With the maintenance channel outside the module and the PDF cabinet supplying power to the air conditioner inside the module, the total area does not exceed 55 m2 and the total height of the module does not exceed 2.65 m. The number of cabinets can be reduced in pairs according to customer requirements.

Advantage
      •  
      •  

        Cost saving

        The micro module data center has independent work and maintenance space, and adopts standardized interfaces. The infrastructure is also planned in this form. The modular data center is equipped with air conditioner to cooperate with the closed channel to complete the sealing of cold and hot channels, so that the near heat source part can directly supply air and shorten the air flow path. The cold and hot passages can isolate the airflow, so that the cold and hot airflow do not interfere with each other, realize the nearby refrigeration of the air conditioner, transfer the heat source, improve the operating efficiency of the air conditioner, reduce unnecessary energy consumption, achieve energy protection and save costs.

        Intelligent management

        The micro module machine room is composed of a variety of structures, such as server cabinet, power distribution cabinet, movable skylight, air conditioner, top wiring trunking, floor, etc. From the overall system perspective, the micro module central machine room can be divided into refrigeration system, lighting system, fire protection system, terminal power distribution system, structural system and monitoring system.

      •  
      • Modular data center solution

        Flexible expansion

        Compared with traditional data centers, micro modules have the advantages of rapid deployment, reduced planning time, increased design and construction speed, and reduced construction cycle. Moreover, the site selection requirements for the project are not high, as long as there is water, electricity and network. In addition, the modular data center can scientifically configure the system structure according to the design scheme to improve the speed of planning and design. For example, the modular product has a short production cycle and unified production regulation, which improves the troubleshooting rate and reduces the workload of infrastructure construction.

  •  
  •  
Specification

 

Equipment System

Item

Parameter

System

Dimension

1200mm enclosed cold/hot aisle dual-row cabinets

1200mm enclosed cold/hot aisle Single-row cabinets

Rack Quantity

Dual Row Racks:≤48Single Row Racks:≤24

Rack

Dimensions

600mm(W)*1200mm(D)*2000mm(H), can be customerized42U

Protection Class

IP20

Enclosed Aisle

Skylight

300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight

Power Supply and Distribution

Dimension

600mm(W)*1200mm(D)*2000mm(H)

UPS Power Supply

380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99

Battery

40AH240AH/12V Valve Regulated Lead Acid Battery

Cooling

Indoor Unit Size

300mm(W)*1200mm(D)*2000mm(H)600mm(W)*1200mm(D)*2000mm(H)

Cooling Capacity

Cooling:2040KWChilled water :2070KWChilled water :2070KW

Power Supply

3Phase 380VAC,50Hz

Air Supply

Front Supply

Type

Enclosed Hot/Cold Aisle

Protection

IP20

Monitoring System

Monitoring

Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm

Equipment monitoring

Power supply, battery, power distribution, air conditioning

 

Application 
  • Small data centers built by government, enterprises and institutions
  • Medium and large data centers providing private cloud services
  • Large data centers for Internet and operators providing public cloud services
  • Meet the customized needs of Internet, communication, government, military, education, electric power, oil and other enterprises
Modular Data Center Solutions I-Module Modular Data Center

 

Solutions    

  

leave a message
Tell us the products/services you’re interested in to get a more accurate quotation tailored to your business.
Related Products
  • Hot &Cold Aisle Containment
    Hot& Cold Aisle Containment With Low PUE

    SHUYI Hot& Cold Aisle Containment is an integrated Modular Data Center Solution which can flexibly adopt the layout of double-row cabinets + cold/hot aisle or single-row cabinets + cold/hot aisle according to user site conditions. Under the two structural layouts, all subsystems such as cabinets, channels, power supply and distribution, refrigeration, security, environmental monitoring and management, and wiring can be integrated according to user needs, providing customers with new data of rapid deployment, high efficiency and energy saving, compact space, and flexible expansion central solution. Power 3N-380V-50HZ Operating Voltage 380v/220v Cooling In-row Precision Air Conditioning UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz Certification CE,ISO Monitoring System Power supply, battery, power distribution, air conditioning,etc.

  • Cabinet Data Center
    Cabinet Data Center Applied In Small Business

    SHUYI I-Rack series intelligent cabinet data center includes the following systems: UPS, power distribution unit, cooling system, cabinet system, wiring system, monitoring and fire systems. It is a kind of integrated solution for IT devices which also provides a safe, reliable and high efficient operation environment for electrical devices. Refrigerant R410a / R407c UPS Capacity 3-10KVA Size 42U for Standard Units Warranty One year Input Power Supply 220V AC 50HZ-60HZ, 120V AC, 380V AC optional Cooling Type DC inverter rack mounted precision air conditioner

  • Prefabricated Modular Data Center
    Server Room Modular Data Center Solutions

    SHUYI I-Module Modular Data Center Solution adopts a modular design and integrates data center infrastructure subsystems such as cabinet systems, channel systems, power supply and distribution systems, air conditioning systems, and monitoring systems to provide customers with rapid deployment, high efficiency, energy saving, a new type of data center with compact space and flexible expansion can effectively meet customers' requirements for efficient, reliable, fast, flexible, and intelligent management of data centers in the cloud era. Power 3N-380V-50HZ Operating Voltage 380v/220v Cooling In-row Precision Air Conditioning UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz Certification CE,ISO Monitoring System Power supply, battery, power distribution, air conditioning,etc.

  • Prefabricated Container Data Center
    Prefabricated Container Data Center Easy Installation And Moving

    Container Data Center means the datacenter is not located in the computer room, but in a large container with being placed in the open space with network and power supply. Containers generally use in-row precision air conditioning for refrigeration, and its biggest advantage is that it occupies a small area. SHUYI I-Container series is a kind of Prefabricated Data Center Solution with the function of power supply and distribution, temperature control, cabinets, management, fire, lightning protection and grounding and so on. It is a highly centralized, multi-purpose data center module featuring high reliability and security, rapid deployment and easy relocation, low cost and low energy consumption. Container Size 20'/40' HQ Rack Quantity 4-10 pcs Single Rack Capacity 3-10KW Rated Power 380/400/415 VAC Cooloing System In-row precision air conditionings Power Supply 25kva*2/25kva*4 N+1 modular UPS

  • Prefabricated container data center
    Efficient Bitcoin Mining Data Center

    SHUYI Bitcoin Mining Data Center (CBMDC) is a MOBILE mining farm which adopts with standard 20ft or 40ft container size for construction. It has excellent facility for migration and can work anywhere after connecting electricity and networks. Stable quality ensures the smooth running which guarantee sustainable good yield. The low power consumption, easy mobility, and high working stability makes it as an iconic design in the cryptocurrency mining industry. Mobile Data Center Size AntMiner units 20Ft Container Size 150 units/20Ft Container Size 40Ft Container Size 300 units/40Ft Container Size Capacity Cooling Type 12kw-75kw Air Cooling Transportability Configuration Support Customized

  • 102KW Data Center PAC
    Data Center Precision Air Conditioning Units

    DataCool series large and medium-sized room-level precision air conditioners adopts international cutting-edge constant temperature and constant humidity technology to meet the increasing demand for ultra-efficient, large capacity precision cooling systems that deliver extremely quiet and accurate climate control for critical data centre applications. The cooling capacity range of Precision Room Cooling System is 20-200kW, suiting most precision cooling applications. There are a variety of air supply and return methods, which can be selected and matched according.

  • Rack Type UPS 1-10KVA
    SY-R Series Rack Type UPS 1-10KVA

    SHUYI SY-R series intelligent high-frequency on-line UPS adopts full digital control technology and the latest high-frequency power conversion technology. It has the characteristics of high efficiency and high power factor. It integrates multiple functions such as AC voltage regulation, backup power supply, and peak surge absorption, which can meet the power protection of harsh grid environment and provide pure, safe and stable power supply for the load. Capacity Input Voltage Range 1KVA -10KVA 110-300VAC Frequency Power Factor 40-70Hz ≥0.99

  • Tower UPS For Data Center
    Soeteck SY-T Series Tower UPS 1-30KVA

    Soeteck SY-T Series UPS are intelligent high frequency pure online UPS, which are generally used on places required high quality electricity, such as hospital equipment, corporations, IT loading equipment, industrial computer terminal. As UPS inverter circuit always in a working state, the stored energy of UPS can be inverted and output alternating current without switching. Capacity Connection Mode 10KVA -30KVA Three phase+Four wire Input Voltage Output Voltage 380/400/415VAC 200/208/220/230/240VAC Frequency Battery Cells 40-70Hz 16-20 optional