SHUYI DataRow In-row Precision Air Conditioning
SHUYI DataRow In-row Precision Air Conditioning
SHUYI DataRow In-row Precision Air Conditioning
SHUYI DataRow In-row Precision Air Conditioning
SHUYI DataRow In-row Precision Air Conditioning

SHUYI DataRow In-row Precision Air Conditioning

SHUYI DataRow Precision Air Conditioning is an in-row cooling solution commonly used in data centers requring higher density cooling with greater efficiency and capacity. The unit is placed beteween the servers in a row for offering cooling close to the heat load, the horizontal airflow pattern supports hot aisles and cold aisles configeration.

 

Direct expansion air-cooled units, water cooled unit, glycol cooled units and chilled water units can meet most of server rooms environment. Wide cooling range can solve the air conditioning solution of the data room with high heat dissipation density under different application environmental conditions.

Cooling Capacity

12-60KW

Cooling Type

Front/Side

Refrigerant

R410A/R407C

Centrigufal Fan

EC Fan

Compressor Type

Inverter Compressor

Air Volume

3200-12500㎥/h

 

 

Features
  • SHUYI In-row precision air conditioning

     

    Efficient - save money and space


    ● Adopt high-efficiency EC fan, with soft-start function, multiple fans are evenly distributed, air flow is uniform without dead angle, and heat exchange efficiency is improved

     

    ●Air is directly drawn from the hot aisle, allowing the unit to take advantage of higher heat transfer efficiency due to higher Delta T.

     

    ●Cold aisle/Hot ailse containment avoids mixing of cold and hot air

     

  • SHUYI In-row PAC Configuration

     

    High intelligence - time saving

     

    ● Standard RS485 communication interface to realize remote monitoring, optional SNMP and TCP/IP interface to improve the efficiency of communication interconnection and meet users' various needs for energy linkage, monitoring and inspection, etc.

     

    ●Intelligent detection of supply voltage, frequency and three- phase imbalance. 

     

    ●Highest protection against downtime, equipment damage and excess wear and tear.

     

    ●Touched screen interface offers the full visibility.

 

Advantages
  • In-row Precision Air Conditioning

    Adopting variable frequency scroll compressor, excellent resistance to liquid impact and lower noise.

    Highly reliable full frequency conversion control, starting current less than rated current and lower impact of power grid.

    Adopting two stage evaporator, add water tray in the middle, effectively prevent blowing water.

    Adopting high-quality components that are strictly tested and certified.

    High strength structure design could ensure solid and reliable

 

Specifications

 

Model SY013 SY025 SY040 SY050 SY060
Air Supply Front/Side Front/Side Front Front Front
Power Supply 380Vac/3Ph/50Hz 380Vac/3Ph/50Hz 380Vac/3Ph/50Hz 380Vac/3Ph/50Hz 380Vac/3Ph/50Hz
Technical Data
Cooling Capacity  (kW) 13.2 26.7 42.6 53.3 63. 9
Sensible Cooling (kW) 13.2 26.7 42.6 53.3 63. 9
Compressor
Refrigerant R410A R410A R410A R410A R410A
Quantity 1 1 1 1 1
Fan
Fan Type EC centrifugal fan EC centrifugal fan EC centrifugal fan EC centrifugal fan EC centrifugal fan
Quantity 4 5 2 3 3
Air Volume (m3/h) 3200 5000 8800 11000 12500
Heater
Heat Type PTC PTC PTC PTC PTC
Capacity  (kW) 2 3 6 6 6
Class 1 1 1 1 1
Humidification
Type Humidifier Humidifier Humidifier Humidifier Humidifier
Capacity (kg/h) 1 1.5 3 3 3
Air Filter G4 G4 G4 G4 G4
Connection Pipe
Humidifier inlet pipe (in) G1/2 G1/2 G1/2 G1/2 G1/2
Drain Pipe Φ (mm) 19 19 19 19 19
Gas Pip Φ(mm) 15.88 19.05 19.05 22 22
Liquid Pipe Φ (mm) 9.52 12.7 15.88 19.05 19.05
           
Indoor Dimension-W*D*H (mm)
Dimension 300*1200*2000
300*1400*2000
300*1200*2000
300*1400*2000
600*1200*2000 600*1200*2000 600*1200*2000
Weight (kg) 190 230 285 310 330
Note:
Standard working conditions: indoor return air dry bulb temperature 37°C, relative humidity 24%, outdoor dry bulb temperature 35°C 

 

Applications

Data center with single rack above 3kW

High heat density computer room

Partially overheated computer room

Modular Data Center

Container Data Center

Low PUE data center

Renovation of local hot spots in the computer room

 In-row Precision Air Conditioning Application

 

Solutions

 

 

 

leave a message
Tell us the products/services you’re interested in to get a more accurate quotation tailored to your business.
Related Products
  • Hot &Cold Aisle Containment
    Hot& Cold Aisle Containment With Low PUE

    SHUYI Hot& Cold Aisle Containment is an integrated Modular Data Center Solution which can flexibly adopt the layout of double-row cabinets + cold/hot aisle or single-row cabinets + cold/hot aisle according to user site conditions. Under the two structural layouts, all subsystems such as cabinets, channels, power supply and distribution, refrigeration, security, environmental monitoring and management, and wiring can be integrated according to user needs, providing customers with new data of rapid deployment, high efficiency and energy saving, compact space, and flexible expansion central solution. Power 3N-380V-50HZ Operating Voltage 380v/220v Cooling In-row Precision Air Conditioning UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz Certification CE,ISO Monitoring System Power supply, battery, power distribution, air conditioning,etc.

  • Cabinet Data Center
    Cabinet Data Center Applied In Small Business

    SHUYI I-Rack series intelligent cabinet data center includes the following systems: UPS, power distribution unit, cooling system, cabinet system, wiring system, monitoring and fire systems. It is a kind of integrated solution for IT devices which also provides a safe, reliable and high efficient operation environment for electrical devices. Refrigerant R410a / R407c UPS Capacity 3-10KVA Size 42U for Standard Units Warranty One year Input Power Supply 220V AC 50HZ-60HZ, 120V AC, 380V AC optional Cooling Type DC inverter rack mounted precision air conditioner

  • Prefabricated Modular Data Center
    Server Room Modular Data Center Solutions

    SHUYI I-Module Modular Data Center Solution adopts a modular design and integrates data center infrastructure subsystems such as cabinet systems, channel systems, power supply and distribution systems, air conditioning systems, and monitoring systems to provide customers with rapid deployment, high efficiency, energy saving, a new type of data center with compact space and flexible expansion can effectively meet customers' requirements for efficient, reliable, fast, flexible, and intelligent management of data centers in the cloud era. Power 3N-380V-50HZ Operating Voltage 380v/220v Cooling In-row Precision Air Conditioning UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz Certification CE,ISO Monitoring System Power supply, battery, power distribution, air conditioning,etc.

  • Prefabricated Container Data Center
    Prefabricated Container Data Center Easy Installation And Moving

    Container Data Center means the datacenter is not located in the computer room, but in a large container with being placed in the open space with network and power supply. Containers generally use in-row precision air conditioning for refrigeration, and its biggest advantage is that it occupies a small area. SHUYI I-Container series is a kind of Prefabricated Data Center Solution with the function of power supply and distribution, temperature control, cabinets, management, fire, lightning protection and grounding and so on. It is a highly centralized, multi-purpose data center module featuring high reliability and security, rapid deployment and easy relocation, low cost and low energy consumption. Container Size 20'/40' HQ Rack Quantity 4-10 pcs Single Rack Capacity 3-10KW Rated Power 380/400/415 VAC Cooloing System In-row precision air conditionings Power Supply 25kva*2/25kva*4 N+1 modular UPS

  • Prefabricated container data center
    Efficient Bitcoin Mining Data Center

    SHUYI Bitcoin Mining Data Center (CBMDC) is a MOBILE mining farm which adopts with standard 20ft or 40ft container size for construction. It has excellent facility for migration and can work anywhere after connecting electricity and networks. Stable quality ensures the smooth running which guarantee sustainable good yield. The low power consumption, easy mobility, and high working stability makes it as an iconic design in the cryptocurrency mining industry. Mobile Data Center Size AntMiner units 20Ft Container Size 150 units/20Ft Container Size 40Ft Container Size 300 units/40Ft Container Size Capacity Cooling Type 12kw-75kw Air Cooling Transportability Configuration Support Customized

  • 102KW Data Center PAC
    Data Center Precision Air Conditioning Units

    DataCool series large and medium-sized room-level precision air conditioners adopts international cutting-edge constant temperature and constant humidity technology to meet the increasing demand for ultra-efficient, large capacity precision cooling systems that deliver extremely quiet and accurate climate control for critical data centre applications. The cooling capacity range of Precision Room Cooling System is 20-200kW, suiting most precision cooling applications. There are a variety of air supply and return methods, which can be selected and matched according.

  • Rack Type UPS 1-10KVA
    SY-R Series Rack Type UPS 1-10KVA

    SHUYI SY-R series intelligent high-frequency on-line UPS adopts full digital control technology and the latest high-frequency power conversion technology. It has the characteristics of high efficiency and high power factor. It integrates multiple functions such as AC voltage regulation, backup power supply, and peak surge absorption, which can meet the power protection of harsh grid environment and provide pure, safe and stable power supply for the load. Capacity Input Voltage Range 1KVA -10KVA 110-300VAC Frequency Power Factor 40-70Hz ≥0.99

  • Tower UPS For Data Center
    Soeteck SY-T Series Tower UPS 1-30KVA

    Soeteck SY-T Series UPS are intelligent high frequency pure online UPS, which are generally used on places required high quality electricity, such as hospital equipment, corporations, IT loading equipment, industrial computer terminal. As UPS inverter circuit always in a working state, the stored energy of UPS can be inverted and output alternating current without switching. Capacity Connection Mode 10KVA -30KVA Three phase+Four wire Input Voltage Output Voltage 380/400/415VAC 200/208/220/230/240VAC Frequency Battery Cells 40-70Hz 16-20 optional

leave a message